8/28/2022

Xhorse VVDI MB W212 Renew ISM Timeout Error Solution

 Problem:

I am trying to virgin a Mercedes Benz w212 2014 ISM with Xhorse VVDI MB Tool but when i try to read it i get “Start transfer/receive data……. time out” and it doesn’t read gets stuck at 5%. This is the second ISM with the same error.
This is my setup and cable i am using.

I am supplying the unit with 12 volt supply.
Xhorse VVDI MB W212 Renew ISM Timeout Error  1

Xhorse VVDI MB W212 Renew ISM Timeout Error 2

Xhorse VVDI MB W212 Renew ISM Timeout Error 3

Xhorse VVDI MB W212 Renew ISM Timeout Error 4

Solution:
Some W212 can be FBS4 system. Last FBS 3 are 1852
DSM may be the FBS4 system. vvdi mb/any tool won’t recognize FBS4.

The only solution is to disassemble and copy the Motorola.
It will be able to renew d file if you can read the Motorola with xhorse vvdi prog after disassembly.
Give it a try.

Continental (DSM)
vvdi prog Continental (DSM)


Siemens (ISM)
vvdi prog Siemens (ISM)